Typical Installations

Straight up installation

For most straight up installations, the only part required is an adjustable length (UBAF). The UBAF adjusts to allow any overall length from 40” to 68”.

90° elbow installation

For most 90° elbow installations, you will only require an elbow (UB90) and an adjustable length (UBAF). If the height from the top of the stove to the top of the elbow is less than 48”, you will require a short length plus a slip section (UBSF) for the vertical section of connector instead of the UBAF.

Damper installation (UBD)

The damper (UBD) allows you to control the air drawn through your chimney. As such, it controls your stove’s combustion. When the handle is in the horizontal position, the damper is closed, creating a restriction in the chimney as far as combustion gases are concerned, and reducing the combustion process inside the stove. (In the close position, the damper is still 20% open so as not to completely block the chimney).

Images

Straight up installation

90° elbow installation

Damper installation (UBD)

View Installation Instructions